Figure 2. Leaking from repair plugs.
Figure 4. Valve coupler with handwheel nut and packing nut.

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  27    28    29    30    31  32  33    34    35    36    37  
img
. . .
0008 00
TM 5-5430-248-13&P
Symptom
Valve coupler cam arms will not lock on to the adapter assembly.
Malfunction
Cam arm (Figure 3, Item 1) will not lock valve coupler to adapter assembly.
Corrective Action
STEP 1. Check that the handwheel (Figure 3, Item 2) is turned completely to the "close"
position.
STEP 2. Replace valve coupler if cam arms will not lock (WP 0012).
2
1
Figure 3. Cam arms will not lock into place.
Symptom
Valve coupler is not stable on the adapter assembly in the locked position.
Malfunction
Valve coupler is missing or has damaged gaskets.
Corrective Action
Replace gasket (WP 0012).
0008 00-3