TROUBLESHOOTING PROCEDURE
Figure 3. Cam arms will not lock into place.

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  26    27    28    29    30  31  32    33    34    35    36  
img
. . .
0008 00
TM 5-5430-248-13&P
1
Figure 2. Leaking from repair plugs.
STEP 1. Check for temporary repairs on the drum body, such as mechanical patches or
wooden plugs.
a. If mechanical patches or wooden plugs have been used to repair the 500
gallon water drum and are now leaking (Figure 2, Item 1), discontinue use of
the drum.
STEP 2. Check for punctures or leaks in the drum body.
a. If hole or tear is less than 2.00" in diameter and if the damage is a:
1. hole, use repair kit WP 0016 to temporarily restore drum.
2. tear, use repair kit WP 0017 to temporarily restore drum.
b. If hole or tear is greater than 2.00" in diameter, discontinue use of drum.
0008 00-2