TEMPORARY REPAIR OF DRUM BODY, METHOD 1
Figure 2. Plug assembly.

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
. . . .
0017 00
TM 5-5430-248-13&P
FIELD LEVEL MAINTENANCE
500 GALLON WATER DRUM DWDM5CG
TEMPORARY REPAIR OF DRUM BODY, METHOD 2
INITIAL SET-UP:
Tools:
Personnel:
Tool Kit, General Mechanic's (WP 0025 00, Item 1)
One (77W)
Materials/Parts Required:
Repair Kit (WP 0026 00, Table 2)
CAUTION
Do not tow drum after using Method 1 to repair
leaking drum. Towing drum could further damage
drum.
NOTE
This procedure only applies if the tear in the drum is
3/8 inch length or less.
After temporary repair, the drum can only be used
until empty.
REPAIR
1. Using rotary cutter, use cutter edge to cut a clean edge around the tear. (Figure 1, Item 1).
1
Figure 1. Cutting edge of the rotary cutter.