Figure 4. Assembly of metal and spacer plates.
Figure 1. Maximum torque limit for 500 gallon water drum

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  67    68    69    70    71  72  73    74    75    76    77  
img
. . . . . .
0014 00
TM 5-5430-248-13&P
8. While holding the metal plate, handtighten the remaining 20 socketcap screws to the spacer
plate.
9. Tighten all 21 socketcap screws to a 45 foot-pounds maximum torque (WP 0015 00).
10. Place swivel plate on the metal plate.
11. Attach bearing plate to the metal plate with ten socketcap screws.
12. Tighten socketcap screws to a maximum of 45 foot-pounds.
13. Repeat installation steps 1 through 13 for other side making sure that the wire rope assemblies
are straight.
14. Install both adapter assemblies (WP 0012 00).
15. Install both valve couplers (WP 0012 00).
TEST
1. Fill drum with drinking water in accordance with (WP 0005 00).
2. Perform PMCS (WP 0011 00, Table 1).
END OF WORK PACKAGE
0014 00-5/6 blank