Figure 3. Components of the 500 gallon water drum to inspect.
REMOVE/INSPECT/INSTALL/TEST SHACKLE, BEARING, SWIVEL PLATE, SPACER PLATE, METAL PLATE, WIRE ROPE - Continued

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  66    67    68    69    70  71  72    73    74    75    76  
img
.
0014 00
TM 5-5430-248-13&P
INSTALLATION
WARNING
Assemble parts on a clean surface. Failure to do so
may cause sickness or injury.
1. Clean all drum parts with a mild, non-toxic detergent with cleaning brush.
2. Install shackle assemblies (WP 0013 00).
3. Take both metal plates so that cable end notches are directly above each other.
4. Unfold and layout drum body. Lubricate edge of metal plate with detergent and insert metal plate
into drum body noting locations of the cable end notches.
5. Reach into drum and attach three wire rope assemblies into the metal plate.
6. Align metal plate to socketcap screw holes.
7. Place spacer plate with the small holed side on the drum body so that the holes line up. Hand
tighten one socketcap screw to the metal plate to hold the position (Figure 4).
Figure 4. Assembly of metal and spacer plates.
0014 00-4