TM 10-4130-237-14
4-25.
ARMATURE GROUP REPLACEMENT/REPAIR (CONT)
c.
To prevent electric shock, be very careful when connecting power cable to
12/24 VOLT INPUT FOR STARTING connection.
3 If electric power available: Insert power cable in 12/24 VOLT INPUT FOR STARTING connection.
Hold toggle switch S3 in START position and press down starter button S7.
NOTE
Two persons may be required for next step.
4 If electric power unavailable: Hold toggle switch S3 in START position and pull starter rope.
5 If spark jumps l/8in. (1/3-cm) gap to ground, system is working.
6 If spark fails to jump l/8in. (1/3-cm) gap to ground, replace/repair armature group.
7 Repeat steps 1 through 6 for left cylinder.
8 Install spark plugs (para 424).
Adjustmen
1 Remove two flywheel pulley mounting bolts and two lockwashers. Remove flywheel pulley.
4-62