TM 10-4130-237-14
4-25.
ARMATURE GROUP REPLACEMENT/REPAIR (CONT)
2
3
4
5
6
7
8
9
Remove eight blower housing mounting bolts. Remove blower housing.
Move starter panel assembly aside.
Insert 0.010 in. (0.254 mm) thickness gage between armature and flywheel with magnet directly in front
of armature.
Loosen two armature mounting bolts. Allow magnet to pull armature down firmly against thickness
gage.
Tighten two armature mounting bolts.
Remove thickness gage.
Install blower housing. Install eight blower housing mounting bolts and starter clamp.
Install flywheel pulley. Install two flywheel pulley mounting bolts and two lockwashers.
4-63