TM 10-4130-237-14
4-29.
HIGH PRESSURE SWITCH CONTINUITY TEST
This task covers testing only.
INITIAL SETUP
Tools
Equipment
Condition
Para
Condition Description
4-8
Engine stopped, power
disconnected, fuel line
disconnected, muffler and
housing removed.
Tools
Common No. 1 Organizational
Maintenance Automotive
Maintenance and Repair
Shop Eqpt, item 2,
appendix B
1 Prepare multimeter for continuity testing.
2 Place red lead of multimeter to top terminal of switch. Place black lead on bottom terminal of switch.
3 Multimeter should show greater than 1 ohm. If multimeter does not show proper continuity, notify direct
support.
4-81