TM 10-4130-237-145-16.EXPANSION VALVE REPLAY (CONT)5 Remove 16 bottom plate mounting screws. Remove bottom plate*Remove tube assembly from expansion valve leading from filter drier.Remove tube assembly from expansion valve leading from evaporator.8Remove expansion valve and bulb assembly.c. Installation6712345Install new expansion valve and bulb assembly.Install tube assembly at expansion valve leading fkom evaporator.Install tube assembly at expansion valve leading from filter-drier.NOTEIf any refrigeration system components have been removed or replaced, in-stall a new filter-drier before evacuating system (para 5-19).Leak-test system (para 5-7).Install bottom plate. Install 16 bottom plate mounting screws.5-53