2.8.6 Preparation for Movement of Distribution Points . (Continued)
ag. Push cam arms on inlet port reducer (5) forward to open. Remove hose assembly (2) from reducer
(5).
ah. Push cam arms on female quick-disconnect coupling half (6) forward to open." "Remove reducer (5)
from female quick-disconnect coupling half (6).
ai. Remove female quick-disconnect coupling half (6) from nipple (7).
aj. Remove nipple (7) from hypochlorination unit (8).
ak. Install plastic dust caps (4) on hypochlorination unit (3) inlet and outlet" "ports.
al. Refer to applicable technical manual and restart 125 GPM pumping assembly (9).
am. Drain storage tank as much as possible. When storage tank is drained, refer" "to applicable
technical manual and shut down 125 GPM pumping assembly (9)." "Continue disconnecting
distribution point.
an. Push cam arms on hose assembly (2) forward to open. Remove hose from male" "quick-disconnect
coupling half (10) on outlet port of 125 GPM pumping assembly" "(9).
ao. Unscrew and remove male quick-disconnect coupling half (10) from 125 GPM" "pumping assembly
(9) outlet port.
ap. Push cam arms on inlet female quick-disconnect coupling half (11) forward to" "open. Remove end
of hose assembly (12) from female quick-disconnect coupling" "half (11) on inlet port of 125 GPM
pumping assembly (9).
aq. Unscrew and remove female quick-disconnect coupling half (11) from 125 GPM" "pumping assembly
(10) inlet port.
ar. Push cam arms on hose assembly (12) forward to open. Remove hose (12) from 2" "inch end of
reducer (13) attached to filler/discharge elbow (14) on 20,000" "gallon pillow tank.
as. Push cam arms on reducer (13) forward to open. Remove reducer (13) from elbow" "(14) on 20,000
gallon pillow tank.
SECTION IV. OPERATION UNDER UNUSUAL CONDITIONS
2.9 OPERATION IN UNUSUAL WEATHER.
The instructions for operation under unusual conditions are provided in paragraphs 2.9.1 through 2.9.5.
2.9.1 600 GPM Pumping Assemblies . For the operation of 600 GPM pumping assemblies under unusual
environmental/weather conditions, reference applicable technical manual.
2.9.2 125 GPM Pumping Assembly . For the operation of 125 GPM pumping assembly under unusual
environmental/weather conditions, reference applicable technical manual.
2.9.3 Hypochlorination Units, Models 1955-3 and A-506131 . For the operation of" "hypochlorination units
models 1955-3 and A-506131 under unusual environmental/weather conditions, reference applicable technical
manual.
2.9.4 20,000 Gallon Pillow Tank. For the operation of 20,000 gallon pillow tank under unusual
environmental/weather conditions, reference applicable technical manual.
2-114