TM 10 4320-303-13
Figure 2-74. Disconnecting 20,000 Gallon Pillow Tank.
n. Disconnect additional discharge hose assemblies as required to reach reducing tee/gate valve
assembly.
2.8.6 Preparation for Movement of Distribution Points . This is a general procedure for moving the
distribution points. For the preparation for movement, disassembly requirements, and disassembly procedures
of the 125 GPM pumping assembly, reference applicable technical manual. For the preparation for movement,
disassembly requirements, and disassembly of the model 1955-3 Hypochlorination unit reference applicable
technical manual and for the model A-506131 Hypochlorination Unit reference applicable technical manual.
2.8.6.1 Disassembly Requirements. Disassembly of a distribution point requires the tools, personnel, and
components referenced in paragraph 2.3.7.1. Pack the components listed in table 2-12 in the "DISTRIBUTION
POINT" crate after removing them from the distribution points.
2.8.6.2 Disassembly Procedures.
WARNING
DANGEROUS CHEMICALS
Calcium hypochlorite can cause injury if not handled properly. Heed safety
measures below.
If calcium hypochlorite comes into contact with skin or eyes, flush right away
with water. Seek medical help.
Mix only in accordance with directions for use.
DO NOT allow calcium hypochlorite to mix with any other materials. This can
cause fire or hazardous gases.
a. Locate packing crate marked "DISTRIBUTION POINT". Remove tubes of calcium hypochlorite (Item
2, Appendix E).
b. Dissolve one tube in each gallon of potable water used to make a cleaning solution.
c. Scrub inside of each 36 gallon drinking water storage bag (Figure 2-75, 1) with solution prepared in
step b.
d. Rinse each drinking water storage bag (1) several times with potable water to get rid of all traces of
cleaning solution prepared in step b. Do not use cleaning solution to rinse drinking water storage
bags.
2-109