TM 10 4320-303-13
2.8.5 Preparation for Movement of Storage Assemblies . (Continued)
Figure 2-73. Disassembly of Storage Assembly Components.
g. Unscrew male coupling half (9) and remove from coupling pipe fitting (7).
h. Push cam arms on discharge hose assembly (10) forward to open. Remove valve assembly (24)
from end of discharge hose (10).
i. Remove eight nuts (12), lock washers (13), flat washers (14), and bolts (15) and flat washers (16).
Remove female quick-disconnect coupling half (8) from 4 inch gate valve assembly (17).
j. Carefully remove gasket (18).
k. Remove eight nuts (19), lock washers (20), flat washers (21), bolts (22) and flat washers (23).
Remove male flanged, quick-disconnect, coupling half (11) from 4 inch gate valve assembly (17).
l. Carefully remove gasket (24).
m. Disconnect first discharge hose assembly (Figure 2-74, 1) from female-to-female filler/discharge
elbow (2) of 20,000 gallon storage tank (3).
2-108