TM10-5430-229-13&P
Table 3-1. Operator Troubleshooting.
MALFUNCT/ON
TEST OR INSPECTION
CORRECTIVE ACTION
1.
TOP COVER HANDLE ASSEMBLIES WILL NOT OPEN.
Examine handles for damage or corrosion.
If handles are damaged or corroded, notify unit maintenance.
2.
END PANEL TURNLOCK ASSEMBLIES WILL NOT LOCK END PANELS
TO SIDE PANELS.
Check that end panels are in upright position.
Place end panels in position so that lettering on end panel is upright. Rotate
turnlocks 90° clockwise to lock handles.
If turnlocks fail to operate properly after turning m counterclockwise manner,
turnlock is damaged. Notify unit maintenance for repairs.
3.
CHANNEL ASSEMBLY LATCHES WILL NOT SECURE TOP COVER.
Step 1. Check for out of adjustment channel latch drawbolt.
Disengage channel assembly latch drawbolt from strike catch of top cover. Rotate
drawbolt either counterclockwise to lengthen drawbolt reach or clockwise to shorten
drawbolt reach and attempt to secure top cover again. Re-adjust length of drawbolt
as required to achieve proper length of drawbolt. If drawbolt will not turn by hand,
notify unit maintenance.
Step 2. Check for damaged channel assembly latch.
If channel assembly latch is damaged in any way, notify unit, maintenance.
4. TIE-DOWN STRAP WILL NOT SECURE STORAGE TANK.
Step 1. Check for loose strap adjustment.
Tighten strap by pulling on loose end of strap located at the tie-down strap buckle.
Step 2. Check tie-down strap for damage.
If tie-down strap is damaged in any way, notify unit maintenance.
Section III. OPERATOR MAINTENANCE PROCEDURES
3-5. GENERAL. No operator maintenance is authorized to the operator of the WTSC.
3-2