TM 10-8110-201-14&P3-12. Drum Tiedown Kita. Side Brackets.Drycleaning solvent, P-D-680, used toclean parts- is potentially dangerous topersonnel and property. Use in a well-ventilated area as the fumes aredangerous if inaled. Avoid repeated andprolonged skin contact. Do not use nearopen flame or excessive heat. Flashpoint of solvent is 100°F - 138°F (38°C -59°C).(1) Wash the brackets (fig. 3-10) in drycleaningsolvent (item 1, App. D), to remove all foreign mat-ter.(2) Inspect side brackets for cracks and bent ormissing parts.(3) Replace unserviceable side brackets withserviceable ones.b. Chain Assemblies.Drycleaning solvent, P-D-680, used toclean parts is potentially dangerous topersonnel and property, Use in a well-ventilated area as the fumes aredangerous if inhaled. Avoid repeatedand prolonged skin contact. Do not usenear flame or excessive heat. Flashpoint of solvent is 100°F - 138°F (38°C -59°C).(1) Wash the front chain assemblies andbrackets (fig. 3-10), intermediate chain assemblies(4) and rear chain assemblies and brackets indrycleaning solvent (item 1, App. D) to remove anyforeign matter.(2) Inspect the chain assemblies for cracked orbroken links and hooks and damaged or missingsleeve.(3) Inspect front and rear brackets for cracksand bends.(4) Replace any unserviceable chain assemblyor chain assembly and bracket with a serviceableone.c. Load Binders.Drycleaning solvent, P-D-680 used toclean parts is potentially dangerous topersonnel and property. Use in a well-ventilated area as the fumes aredangerous if inhaled. Avoid repeatedand prolonged skin contact. Do not usenear open flame or excessive heat. Flashpoint of solvent is 100°F - 138°F (38°C -59°C).(1) Wash the load binders (fig. 3-10) indrycleaning solvent (item 1, App. D) to remove anyforeign matter.(2) Inspect the load binders for cracked,broken, bent or missing parts.(3) Replace unserviceable load binders.3-13. Repair Kit, Type I.a. Cleaning and Inspection.Drycleaning solvent, P-D-680, used toclean parts is potentially dangerous topersonnel and property. Use in a well-ventilated area as the fumes aredangerous if inhaled. Avoid repeatedand prolonged skin contact. Do not usenear open flame or excessive heat. Flashpoint of solvent is 100°F - 138°F (38°C -59°C).(1) Wash the pliers (1, fig. 3-5) and the rotarycutter in drycleaning solvent (item 1, App. D), anddry them with a clean cloth.(2) Using a stiff bristle brush, remove foreign matter from the pouch (2).(3) Wash the face protective hood (4) with clear water, and dry it with a clean cloth.(4) Using a mild soap and water solution with astiff bristle brush, remove foreign matter fromwood plugs (6) and mechanical patches (7).(5) Inspect the pouch for rips and broken ormissing snap fasteners.(6) Inspect the pliers and rotary cutter forcracks and excessive wear.3-14
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business