SERVICE MANUALWATER PUMP, THERMOSTAT & IDLER PULLEYSSection 9CG-5967Figure 44. - Tool Fabrication Dimensionsfor Holding Shaft14.Apply 102 N•m (75 Ibf-ft) torque to nut and shaftas shown in Figure 45.Figure 45. - Torquing Nut1.Tool15.Install plug (1, Fig. 39), into bracket.16.Install idler onto engine.17.Install belts. Refer to the Operator's Manual forbelt adjusting procedures.PROCEDURE FOR AIR COMPRESSORIDLERPULLEY.DISASSEMBLYDisassemble the Air Compressor Idler Pulley (NewStyle) as follows: (See Fig. 46)1.With suitable tool, press bearing (3, Fig. 46) outfrom idler bracket (5).2.Remove front retaining ring (1) from pulley (2).3.Remove rear retaining ring (4).4.Press bearing (3) from pulley (2).Figure 46. - New Style1.Ring, front retaining2.Pulley, air compressor idler3.Bearing (with shaft), idler4.Ring, rear retaining5.Bracket, idler support6.Bolt, 1/2 - 13 x 3/47.Washer, 1/2 hardenedCGES-185-3PRINTED IN UNITED STATES OF AMERICAPage 26
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business