SERVICE MANUALROBERT BOSCH MODEL MW INJECTION PUMPSection 11Figure 35. - Outer Throttle Control LeverREPLACING OR REPAIRING ELECTRIC SHUTOFFSOLENOID, MOUNTING BRACKET, ADJUSTING RODAND ROD END AND ADJUSTING LINKAGE (FIGURE36)All Cargostar vehicles are equipped with electricshutoffs. If a vehicle was originally equipped with cableshutoff, electric shutoff can be field installed.Figure 36.Follow these procedures step by step to prevent solenoidburnout or internal damage to injection pump.1.Remove solenoid plunger from solenoid and capopening.2.Assemble solenoid to bracket and tighten bolts.3.Assemble bracket to engine at front cover andcrankcase mounting locations.4.Assemble rod end to shutoff lever and tighten bolt.DO NOT connect rod end to adjusting rod at thistime.5.Thread adjusting rod to solenoid plunger untilbottomed, then tighten locknut.6.Reinstall plunger into solenoid, depress plunger tobottom, energize solenoid using a 12 volt D.C. powersource with 8 ampere "slow blow" fuse protection(Figure 37). Be sure that positive lead is connectedto positive terminal, negative to negative. Whensolenoid is mounted to engine, the positive terminalwill be closest to engine water pump and thenegative terminal will be between the positiveterminal and the unused auxiliary terminal. Theauxiliary is closest to flywheel housing. Solenoid isto be energized through step 7.Figure 37.CGES-185-3PRINTED IN UNITED STATES OF AMERICAPage 24