TM 5-3825-226-24
CARRY CHECK VALVE FOR LIFT CYLINDERS
REMOVE CARRY CHECK VALVE FOR
LIFT CYLINDERS
WARNING: Lower the water distributor onto
suitable support and release all pressure from the
hydraulic system before any lines are disconnected.
1.
Disconnect hose assemblies (1) and (2) from
valve body (3).
2.
Remove four bolts (4) and remove valve body
(3) from the lift cylinder.
3.
Remove O-ring seal (6) from valve body (3).
4.
Remove fitting (5), the spring and the valve
from valve body (3). Remove the O-ring seal
from fitting (5).
INSTALL
CARRY
CHECK
VALVE
FOR
LIFT
CYLINDERS
1.
Install valve (3) and spring (2) in valve body (1).
2.
Install the O-ring seal on the fitting that holds
valve (3) and spring (2) in position.
3.
Install O-ring seal (4) and valve body (1).
4.
Put valve body (1) in position on the lift cylinder
and install the four bolts that hold it.
5.
Connect the pilot hose assembly and hose
assembly (5) to valve body (i).