TM 5-3825-226-24
LIFT CYLINDERS
REMOVE LIFT CYLINDERS
1.
Lower the water distributor onto suitable support
before the hydraulic lines are disconnected.
2.
Disconnect hose assembly (1) from cylinder
assembly (2).
3.
Remove the four bolts that hold carry check
valve (3) to cylinder assembly (2).
4.
Fasten a hoist to cylinder assembly (2).
5.
Remove the two bolts (4), plate (6) and pin (5)
that hold the rod end of cylinder assembly (2) to
the water distributor.
6.
Remove the two bolts, plate and pin (7) that
hold cylinder assembly (2) and remove the
cylinder assembly from the machine. The
weight of the cylinder assembly is 105 lb. (47.3
kg).
INSTALL LIFT CYLINDERS
1.
Fasten a hoist to cylinder assembly (2) and put
the rod end in position in the water distributor.
2.
Install pin (1) to hold the rod end of the cylinder
assembly.
6-9