TM 5-3825-226-24
WATER PUMP PRIMING VALVE,
SIGHT GAUGE, SPRAY HEAD
REMOVE PUMP PRIMING VALVE
1. Remove the valve lever linkage (1).
2.
Remove the pump hose (2).
3.
Unscrew the pump priming valve (3) from the
priming tank outlet.
INSTALL PUMP PRIMING VALVE NOTE: Apply a
suitable sealant to valve threads.
1.
Screw the pump priming valve (3) onto the tank
outlet until the valve is tight and the lever aligns
with the linkage (1).
2.
Attach the valve lever linkage (1).
3.
Attach the pump hose (2).
REMOVE SIGHT GAUGE
1.
Close the gate valve (1) (clockwise).
2.
Unscrew the two hose couplings (2).
3.
Remove the plastic hose (3).
INSTALL SIGHT GAUGE
1.
Position the plastic hose on the tank and secure
with the two hose couplings (2).
2.
Open the gate valve (I) (counterclockwise).
REMOVE SPRAY HEAD
1.
Remove nuts (1) and bolts (2) that secure anti-
vibration coupling (3).
2.
Remove anti-vibration coupling (3).
3.
Remove spray head (4).
INSTALL SPRAY HEAD
1.
Align spray head (4) correctly with piping (5).
2.
Install anti-vibration coupling (3).
6-32