TM 5-3825-229-14&P
Table 4-2. Organizational Troubleshooting Table (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE (cont)
1.
ENGINE WILL NOT TURN OR CRANK (cont)
Step 2.
Test for 12 volts DC at starter.
a.
Replace starter if necessary (para. 4-59).
b.
If there is 12 volts DC through starter, go to step 3.
Step 3.
Test for 12 volts DC at starter solenoid.
a.
Replace solenoid if necessary.
b.
If there is 12 volts DC through solenoid, go to step 4.
Step 4.
Test for 12 volts DC at starter relay.
a.
Replace relay if necessary.
b.
If there is 12 volts DC through relay, go to step 5.
Step 5.
Test starter switch (para. 4-12).
a.
If switch is faulty, replace switch (para. 4-12).
b.
If switch is good, go to step 6.
Step 6.
Test starter motor (para. 4-59).
a.
If starter motor is faulty, replace (para. 4-59).
b.
If starter motor is good, notify Direct Support/General Support Maintenance.
2.
ENGINE CRANKS BUT WILL NOT START
Step 1.
Check for fuel in tank.
Step 2.
Check for 12 volts DC at fuel solenoid.
Step 3.
Test battery. Refer to TM 9-6140-200-14.
a.
Charge or replace battery if necessary (para. 4-22).
b.
If battery is good, go to step 4.
4-7