TM 5-3895-370-14&PNOTE·Place suitable container under liftpump.·Cap and plug all hoses and tubesafter removal.(1)Remove two screws (1), lift pump (2), andgasket (3) from cylinder block (4). Discardgasket.(2)Remove suitable container and dispose offuel in accordance to local regulations.b.Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc.).(1)Clean lift pump and elbow in drycleaning solvent and dry with compressed air.(2)Inspect camshaft lever and return spring for excessive wear. If damaged, replace lift pump.4-73
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business