TM 5-3895-370-14&P4-53. RADIATOR ASSEMBLY AND SUPPORT REPLACEMENT/REPAIR (CONT).(3)Remove eight screws (6), washers (7),and radiator (4) from radiator support (3).(4)Remove eight screws (8), washers (9), twoclamps (10), overflow hose (11), andradiator shroud (12) from radiator (4).(5)Remove overflow hose (11) and cap (13)from radiator (4).(6)If damaged, remove two clamps (10) fromoverflow hose (11).b.Cleaning/InspectionWARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(1)Clean radiator and all metal parts with drycleaning solvent and lint-free cloth.WARNINGCompressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Useonly with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc.).(2)Dry radiator and all metal parts with compressed air or lint-free cloth.4-134
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business