TM 5-3895-370-14&P
4-87. 24-VOLT CABLE REPLACEMENT (CONT).
NOTE
Tag and mark all wires before
removal.
(4)
Disconnect two wires (11) from two diodes (12).
(5)
Disconnect wire (13) from bottom resistor (14).
(6)
Disconnect two wires (15) from two top resistors
(16).
(7)
Remove and discard cable tie (17) from cable
(4).
(8)
Remove cable (4) from resistor box (10).
b.
Installation.
(1)
Install cable (4) in resistor box (10).
(2)
Install cable tie (17) on cable (4).
(3)
Connect two wires (15) on two top resistors (16).
(4)
Connect wire (13) on bottom resistor (14).
(5)
Connect two wires (11) on two diodes (12).
(6)
Install cover (9) on resistor box (10) with four
screws (8).
(7)
Install cable (5) in clip (6).
(8)
Install ground wire (6), washer (5), clip (4), cable
(3), lockwasher (2), and nut (1) on main frame
(7).
NOTE
Follow-on
maintenance:
Connect
negative battery cable (para 4-84).
END OF TASK
4-234