TM 5-3895-370-14&P4-87. 24-VOLT CABLE REPLACEMENT (CONT).NOTETag and mark all wires beforeremoval.(4)Disconnect two wires (11) from two diodes (12).(5)Disconnect wire (13) from bottom resistor (14).(6)Disconnect two wires (15) from two top resistors(16).(7)Remove and discard cable tie (17) from cable(4).(8)Remove cable (4) from resistor box (10).b.Installation.(1)Install cable (4) in resistor box (10).(2)Install cable tie (17) on cable (4).(3)Connect two wires (15) on two top resistors (16).(4)Connect wire (13) on bottom resistor (14).(5)Connect two wires (11) on two diodes (12).(6)Install cover (9) on resistor box (10) with fourscrews (8).(7)Install cable (5) in clip (6).(8)Install ground wire (6), washer (5), clip (4), cable(3), lockwasher (2), and nut (1) on main frame(7).NOTEFollow-on maintenance: Connectnegative battery cable (para 4-84).END OF TASK4-234