TM 5-3895-370-14&Pb. Installation.(1)Install hydraulic hoses as follows:WARNINGAdhesive sealant, MIL-S-46163, candamage your eyes. Wear safetygoggles/glasses when using; avoidcontact with eyes. If sealant contactseyes, flush eyes with water and getimmediate medical attention.NOTEApply hydraulic sealant to hosethreads.(a)Install reducer (5) and tee (2) on strainer(6).(b)Install tee (2) on reducer (5) then installreducer (4) on tee.(c)Install hose (3) on reducer (4) and hose(1) on tee (2).(2)Install fittings as follows: NOTE Apply hydraulicsealant to pipe threads.(a)Install two nipples (12) on valve (13).(b)Install valve (13) and nipples (12) onhydraulic tank (14) as an assembly.(c)Install filter head (11) on nipple (12).(d)Install elbow (10) on filter head (11).(e)Install elbow (8) on pipe (9) then installpipe (9) on elbow (10).(f)Install hose (7) on elbow (8).NOTEFollow-on maintenance: Fill hydraulic tank (para 4-143).4-359