b. Installation.
(1)
Install hydraulic hoses as follows:
WARNING
Adhesive sealant, MIL-S-46163, can
damage your eyes. Wear safety
goggles/glasses when using; avoid
contact with eyes. If sealant contacts
eyes, flush eyes with water and get
immediate medical attention.
NOTE
Apply hydraulic sealant to hose
threads.
(a)
Install reducer (5) and tee (2) on strainer
(6).
(b)
Install tee (2) on reducer (5) then install
reducer (4) on tee.
(c)
Install hose (3) on reducer (4) and hose
(1) on tee (2).
(2)
Install fittings as follows: NOTE Apply hydraulic
sealant to pipe threads.
(a)
Install two nipples (12) on valve (13).
(b)
Install valve (13) and nipples (12) on
hydraulic tank (14) as an assembly.
(c)
Install filter head (11) on nipple (12).
(d)
Install elbow (10) on filter head (11).
(e)
Install elbow (8) on pipe (9) then install
pipe (9) on elbow (10).
(f)
Install hose (7) on elbow (8).
NOTE
Follow-on maintenance: Fill hydraulic tank (para 4-143).
4-359