TM 5-3895-370-14&P
4-135. HYDRAULIC CONTROL LEVERS AND LINKAGE REPLACEMENT (CONT).
b. Installation.
NOTE
Apply silicone grease to all pins prior
to installation.
(1)
Install linkage (7) on control valve (4) and secure
with pin (6).
(2)
Install snap ring (5) on pin (6).
(3)
Install lever (3) on control valve (4) and secure
with two pins (2).
(4)
Install two snap rings (1) on pins (2).
NOTE
Follow-on maintenance: Install hydraulic control bank assembly (para 4-134).
END OF TASK
4-356