TM 5-3895-370-14&P4-148. WATER TEMPERATURE SENSOR/GAGE REPLACEMENT (CONT).(3)Remove screw (4), clip (5), and lead (6) fromcylinder block (7).(4)Remove sensor lead (6) from clip (5).(5)Remove four nuts (8), lockwashers (9), clips(10), and conduit (11) from main frame (12).Discard lockwashers.(6)Cut plastic ties as necessary and removeconduit (11) from four clips (10).4-414