TM 5-3895-370-14&Pb. Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;use only in a well-ventilated area; avoid contact with skin, eyes, and clothes and do not breathevapors. Keep away from heat or flame. Never smoke when using solvent; the flash point fortype I drycleaning solvent is 100°F (38°C) and for type II is 140°F (60°C). Failure to do so mayresult in injury or death to personnel. P-D-680 type III is a substitute for types I and II in thisapplication. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,immediately flush eyes with water and get immediate medical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only witheffective chip guarding and personal protective equipment (goggles/shield, gloves, etc.).(1)Clean all components with drycleaning solvent and dry with compressed air.(2)Inspect valves for proper operation.(3)Inspect nozzle for clogging.(4)Inspect all other components for cracks, worn threads, and obvious damage.(5)Replace all damaged parts.c. Assembly.NOTEApply pipe thread sealant to threadsof spray pipe, reducer, adapter, andnozzle prior to assembly.(1)Assemble nozzle (18), reducer (17), and elbow(15) on spray pipe (16).(2)Install nipple (13) on valve (14).(3)Install valve (14) on spray pipe (16).4-461