TM 5-3895-370-14&P
c. Cleaning/lnspection.
WARNING
· Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles
and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes and do not breathe vapors. Keep away from heat or flame. Never smoke
when using solvent; the flash point for type I drycleaning solvent is 100°F (38°C)
and for type II is 140°F (60°C). Failure to do so may result in injury or death to
personnel. P-D-680 type III is a substitute for types I and II in this application. The
flash point for type III is 200°F (93°C).
· If personnel become dizzy while using cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or clothes, flush with cold water. If
solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
(1)
Clean all metal parts with drycleaning solvent.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only
with
effective
chip
guarding
and
personal
protective
equipment
(goggles/shield, gloves, etc.).
(2)
Dry all parts with compressed air.
(3)
Check all parts for damage.
(4)
Replace damaged parts.
d. Assembly.
(1)
Press seal (42) into pump housing (20).
(2)
Install washer (41), sealing washer (40), and
screw (39) into pump housing (20).
(3)
Install two bearings (38) and seals (37) in pump
housing (20).
(4)
Press bearing cup (36) into pump housing (20).
(5)
Press bearing cone (35) onto pump shaft (30).
5-115