TM 5-3895-370-14&P
5-38. HYDRAULIC FIXED-SPEED PUMP REPLACEMENT/REPAIR (CONT).
e.
Installation.
NOTE
Apply hydraulic fluid
to preformed packings
before installation.
(1)
Install two preformed packings (10) on two
elbows (9).
(2)
Install two elbows (9) on fixed-speed pump (3).
Tighten two nuts (8).
(3)
Install gasket (6) and fixed-speed pump (3) on
variable-speed pump (7) with two washers (5)
and screws (4).
NOTE
Refer to tags to properly install
hydraulic lines.
(4)
Connect two hoses (1 and 2) on fixed-speed
pump (3).
NOTE
Follow-on
maintenance:
close
hydraulic valves (para 4-143).
END OF TASK
5-126