TM 5-3895-370-14&PWARNINGCompressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Useonly with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc).(8) Clean cylinders bores with detergent and hot water. Rinse with clean water and dry with compressed air.(9) Check cylinder bores for residue. If residue is found, repeat step (8).WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective gogglesand gloves; use only in a well-ventilated area; avoid contact with skin, eyes, andclothes and do not breathe vapors. Keep away from heat or flame. Never smokewhen using solvent; the flash point for type I drycleaning solvent is 100°F (38°C)and for type II is 140°F (60°C). Failure to do so may result in injury or death topersonnel. P-D-680 type III is a substitute for types I and II in this application. Theflash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get fresh airand medical help. If solvent contacts skin or clothes, flush with cold water. Ifsolvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(10)Wash cylinder block in drycleaning solvent and clean out oil passages with long nylon brush.WARNINGCompressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Useonly with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc).(11)Rinse block in drycleaning solvent and dry with compressed air.5-257