TM 5-3895-370-14&P5-62. GATE VALVE ASSEMBLY REPAIR (CONT).(6)Install cap (10) on valve body (8).NOTEInstall preformed packings with onebevel edge towards stuffing box andone bevel edge towards gland.(7)Install two preformed packings (9) in stuffing box(6).(8)Install stuffing box (6) and two preformedpackings (9) on stem (7).(9)Install gland (5), gland spring (4), and nut (3) onstem (7).(10)Install handle (2) and tighten handle nut (1).NOTEFollow-on maintenance: Install gate valve (para 5-59).END OF TASK5-252