TM 5-3895-370-14&P
WARNING
Compressed air is used for cleaning purposes and will not exceed 30 psi (207 kPa).
Use only with effective chip guarding and personal protective equipment (goggles,
gloves, etc.).
(2)
Dry all parts with compressed air.
(3)
Check parts for damage.
(4)
Replace damaged parts.
c. Assembly.
(1)
Install disc set (12) on lever (11).
NOTE
Orientate lever to valve body with
stop up and taper down.
(2)
Install lever (11) and disc set (12) into valve
body (8).
(3)
Insert stem (7) in lever (11) and place handle (2)
on stem.
NOTE
To
close
valve
rotate
handle
counterclockwise.
(4)
Rotate lever (11) and disc set (12) to the closed
position using handle (2).
(5)
Remove handle (2) from stem (2).
5-251