TM 5-3895-370-14&PWARNINGCompressed air is used for cleaning purposes and will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment (goggles,gloves, etc.).(2)Dry all parts with compressed air.(3)Check parts for damage.(4)Replace damaged parts.c. Assembly.(1)Install disc set (12) on lever (11).NOTEOrientate lever to valve body withstop up and taper down.(2)Install lever (11) and disc set (12) into valvebody (8).(3)Insert stem (7) in lever (11) and place handle (2)on stem.NOTETo close valve rotate handlecounterclockwise.(4)Rotate lever (11) and disc set (12) to the closedposition using handle (2).(5)Remove handle (2) from stem (2).5-251