TM 10-4130-237-14
4-27.
STARTER REPLACEMENT
(CONT)
To prevent
electric shock
, make sure power is disconnected from 12/24 VOLT
INPUT FOR STARTING connection before performing this procedure.
b.
Starter
Cable
Replacment
1
2
3
4
5
6
Remove cable nut and internal toothed washer from starter. Remove starter cable.
Remove starter cable mounting clamp bolt from blower housing. Remove starter cable mounting clamp
from starter cable.
Remove starter cable mounting nut, lockwasher, and flatwasher from switch S7. Remove starter cable.
Install starter cable on switch S7. Install flatwasher, lockwasher, and starter cable mounting nut.
Install starter cable mounting clamp on starter cable. Install starter cable mounting clamp and bolt on
blower housing.
Install starter cable on starter. Install internal toothed washer and cable nut on starter.
4-71