TM 10-4320-303-134.8.2 SpecialInstructions. Preventive maintenance is not limited to performing only those checks andservices listed in the PMCS Table. Covering unused receptacles, stowing unused accessories, and otherroutine procedures such as equipment inventory, cleaning components, and touch-up painting are not listed inthe table. These are things you should do any time you see that they need to be done. If a routine check islisted in the PMCS Table, it is because experience has shown that problems may occur with this item. Takealong tools and cleaning cloths needed to perform the required checks and services.Table 4-6. Unit Maintenance Preventive Maintenance Checks and Services.LocationItemNo.IntervalItem toCheck/ServiceProcedureNot FullyMission Capableif:HypochlorinationUnit1955-11WeeklyStrainer AssemblyRefer to paragraphStrainer is4.13.4. and servicedamaged orstrainer assembly.corroded.Inspect for corrosionor damage.SECTION IV. UNIT TROUBLESHOOTING4.9 TROUBLESHOOTING .The malfunction index lists faults that may be observed by unit maintenance personnel. The faults are thencross-referenced to the troubleshooting table, Table 4-7. Table 4-7 contains information useful in diagnosingand correcting unsatisfactory conditions which may be encountered during operation or maintenance of theTWDS. Use the malfunction index to locate specific troubleshooting procedures contained in Table 4-7. Afterlocating the troubleshooting procedure, perform the test/inspections and corrective actions in the order listed.The malfunction index and Table 4-7 cannot list all of the malfunctions that may occur, all tests and inspectionsneeded to find the fault, or all the corrective actions needed to correct the fault. If the equipment malfunction isnot listed or actions listed do not correct the fault, notify your supervisor. Refer to the applicable technicalmanuals for 125 GPM and 600 GPM Pumping Assemblies, Hypochlorination Units, and for 20,000 GallonPillow Tank unit troubleshooting procedures.UNIT MALFUNCTION INDEXMalfunction Numberin Table 4-720,000 Gallon Pillow Tank is not being filled.............................................................................1Pressure-reducing valve assembly will not open or will notclose drip-tight..........................................................................................................................2Hypochlorination unit, model 1955-1 pressure gauge showshigh pressure............................................................................................................................3Hypochlorination unit, model 1955-1 camshaft is turning butspring is not moving..................................................................................................................4Little or no water flow at distribution points................................................................................54-10
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business