Table 4-7. Unit Troubleshooting Table. (Continued)
TWDS SUPPLY CONNECTION ITEMS MAINTENANCE
TM-10-4320-303-13 Tactical Water Distribution Equipment System (TDWS) Set 10-Mile Segement Model 06749-0813-81 110-00-0000 919 and 10 Manual
Page Navigation
153
154
155
156
157
158
159
160
161
162
163
TM 10-4320-303-13
SECTION V. UNIT MAINTENANCE PROCEDURES
4.10
TWDS
SUPPLY
CONNECTION
ITEMS
MAINTENANCE
.
4.10.1 Reducer Y-Connection Maintenance.
This task covers:
4.10.1.1
Removal
4.10.1.4
Repair
4.10.1.2
Disassembly
4.10.1.5
Assembly
4.10.1.3
Inspection'
4.10.1.6
Installation
INITIAL SETUP
Tools
Equipment Conditions
Tool Kit, General Mechanic's,
Lead pumping station shutdown, refer to
Automotive, Section III, Item 1,
applicable technical manual.
Appendix B
Material/Parts
General
Safety
Instructions
Do not work on equipment without following
Antiseize Tape, Item 9, Appendix E
standard shop safety precautions.
Silicon Lubricant, Item 5, Appendix E
Gasket (TM 10-4320-303-23P)
4.10.1.1
Removal
.
Figure 4-1. Reducer Y-Connection Removal.
a. Open cam arms and disconnect reducer Y-connection (Figure 4-1, 1) from water source.
4-13