TM 10-4320-346-12&P4-13.BALL VALVE ASSEMBLY, 2.00 INCH, QUICK ACTING.This Task Covers:RepairInitial Setup:ToolsRequiredTool Kit, General Mechanic's (Appendix B, Item 1)Wrench, Pipe (Appendix B, Item 2)Material'sRequiredBrush, Medium Bristle (Appendix F, Item 2)Solvent, Dry Cleaning (Appendix F, Item 3)Cloth, Lint-Free (Appendix F, Item 1)Sealing Compound (Appendix F, Item 4)Gaskets (Appendix I, Item 1)Equipment ConditionAssembly removed from FAWPSS installation.Repair.(Refer to Figure 4-3.)NOTERepair is limited to replacement of parts found defective during inspection.a.Disassembly.(1)Remove quick disconnect cap (1) and gasket (2) from male coupling half (3).(2)Remove quick disconnect plug (4) and gasket (5) from female coupling half (6).(3)Remove male coupling half (3) and female coupling half (6) from ball valve assembly(7).b.Clean.(1) Remove all build up of dirt, oil, and debris from all mating surfaces and clamping areas.WARNINGDO NOT breath dry cleaning solvent vapors for long periods of time or allowsolvent to come into contact with skin for an extended time. DO NOT use solventnear open flames or excessive heat.(2) Clean all metallic parts with a clean soft cloth (Appendix F, Item 1) or a medium bristlebrush (Appendix F, Item 2), and cleaning solvent (Appendix F, Item 3).(3) Allow parts to dry.4-10
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business