TM 10-4610-237-122.7 ASSEMBLYANDPREPARATIONFORUSE-Continued.(4) Remove cap (5) from male coupling (6).(5) Position male coupling (6) in female coupling (2) and hold in place.(6) Pull both locking arms (1) back at the same time until arms are down against body of female coupling(2).(7) Verify that male coupling (6) and female coupling (2) are connected by pulling on couplings. Couplingsshould remain securely connected and locking arms (1) must remain snug against coupling body.Disconnection.WARNINGDo not disconnect hose couplings while water system is pressurized. Hose ends may whip,causing injury to personnel and damage to equipment.(8) Pull locking arms (1) up and out from female coupling (2).(9)Pull female couplings (2) from male couplings (6).(10) Insert plug (3) in female coupling (2) and pull locking arms (1) back against coupling body.(11) Place cap (5) over male coupling (6) and pull locking arms (4) back against cap body.d.InstallWaterTank.NOTEA lifting device is required to remove the collapsible fabric tank from the storage chest andposition the tank at the installation site. Notify unit maintenance to assist you with positioningheavy components.(1) Place water tank in position at installation site.(2) Assemble and prepare water tank for use in accordance with the applicable TM.e.AssembleSingleTankConnectionKit. (Refer to Figure 2-5)WARNINGTo prevent contamination of drinking water make sure water tank elbows are capped and pluggedwhen system hoses are not connected to tank. Do not remove caps and plugs from componentsuntil couplings are ready to be connected.2-17
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business