TM 10-4610-243-132-10. ASSEMBLY AND PREPARATION FOR USE - cont.o.Assemble Hose and Nozzle Kits. Refer to figure 2-22.WARNINGTo prevent contamination of drinking water, make sure protective caps andplugs are installed when components are not in use. Do not remove caps andplugs from components until couplings are ready to be connected.NOTEA 2 inch female x 1-½ male adapter is supplied with each hose and nozzlekit for connecting the kits directly to a 2 inch discharge hose. Theseadapters will not be used in this assembly procedure. Your operatingconditions may require use of the adaptersThree hose and nozzle kits are used in the water system. Kit no 1 is shown,kit no. 2 and 3 are similar.(1)Connect adapter (1-½ inch female x 1 inch male) (2) to 1-½ inch x 25 foot discharge hose (1)(from bag filler connection kit).(2)Connect two 1 inch x 10 foot discharge hoses (3 and 4) to adapter (2).(3)Connect regulator (5) to 1 inch x 10 foot discharge hose (4). Make sure regulator is positionedwith wooden base down on ground.(4)Connect two 1 inch x 10 foot discharge hoses (6 and 7) regulator (5).(5)Connect distribution nozzle (8) to 1 inch x 10 foot discharge hose (7).(6)Unfold nozzle stand assembly (9) and attach distribution nozzle (8) to bracket on stand.(7)Repeat steps (1) through (6) for kit no 2 and no 3.2-58