TM 10-4610-243-13
2-10. ASSEMBLY AND PREPARATION FOR USE - cont.
o.
Assemble Hose and Nozzle Kits. Refer to figure 2-22.
WARNING
To prevent contamination of drinking water, make sure protective caps and
plugs are installed when components are not in use. Do not remove caps and
plugs from components until couplings are ready to be connected.
NOTE
A 2 inch female x 1-½ male adapter is supplied with each hose and nozzle
kit for connecting the kits directly to a 2 inch discharge hose. These
adapters will not be used in this assembly procedure. Your operating
conditions may require use of the adapters
Three hose and nozzle kits are used in the water system. Kit no 1 is shown,
kit no. 2 and 3 are similar.
(1)
Connect adapter (1-½ inch female x 1 inch male) (2) to 1-½ inch x 25 foot discharge hose (1)
(from bag filler connection kit).
(2)
Connect two 1 inch x 10 foot discharge hoses (3 and 4) to adapter (2).
(3)
Connect regulator (5) to 1 inch x 10 foot discharge hose (4). Make sure regulator is positioned
with wooden base down on ground.
(4)
Connect two 1 inch x 10 foot discharge hoses (6 and 7) regulator (5).
(5)
Connect distribution nozzle (8) to 1 inch x 10 foot discharge hose (7).
(6)
Unfold nozzle stand assembly (9) and attach distribution nozzle (8) to bracket on stand.
(7)
Repeat steps (1) through (6) for kit no 2 and no 3.
2-58