TM 5-3820-256-10
5
Connect neutral lead to terminal B on terminal strip 1T.
6
Connect ground lead from terminal C on terminal strip 1T to ground terminal below terminal strip
1T.
7
Connect ground lead to ground terminal below terminal strip 1T.
8
Tighten strain relief on the generator rear panel.
9
Install right side welder/generator panel and resume operation.
(h)
Place weld/power switch in POWER position. See Figure 2-32.
NOTE
Fine amperage control can be adjusted while welding. However, fine amperage control must be set at
100 to obtain the full-rated output from the 120 Volt, 30 Amp ac receptacle when the welder/generator is
used to supply ac power.
(i)
Rotate fine amperage control to 100.
(j)
Start engine per instructions in paragraph "c", step (1), above.
(k)
Turn on auxiliary equipment when engine is at proper speed.
2-13.
Fuel Transfer System.
a. Assembly and Preparation for Use. The fuel transfer system is pre-assembled and ready for use.
b. Initial Adjustments, Daily Checks, and Self Test. This equipment requires no initial adjustments or self-tests.
c. Operating Procedure. The fuel transfer pump, a 12-volt electric power pump, is not a continuous duty pump. It
has a 12-volt electric motor that is subject to overheating and burnout with prolonged usage. The fuel pump has
a 13-gallon per minute delivery, and the diesel fuel tank has a 200-gallon capacity.
CAUTION
When using maximum delivery capacity, do not operate the fuel pump longer than 20 minutes to pump
the tank dry.
(1)
Set the cab-mounted ON/OFF switch (1, figure 2-17) in ON position.
(2)
Unlock and open the fuel storage box.
(3)
Remove the pump nozzle and fill hose from the storage box and insert the nozzle into the diesel fuel tank
opening.