SERVICE MANUALFig. 37 Retainer Ring In Housing1 Retainer Ring12.Thread the retainer ring into pump body fingertight. Install the "UP" side of the ring up, Figure37.13.Lubricate the flow control valve bore with thesame type of lubricant as used in pump. Insertthe valve assembly into the bore with the longsmall diameter end in first, Figure 38. The valvemust slide smoothly in the bore. Place the flowcontrol valve spring in the valve bore and installthe valve cap finger tight.14.Install new O-ring on discharge fitting (Figure 39)and install fitting in housing finger tight.15.Clean mating surfaces and install the pumpmounting flange using a new O-ring (gear drivenpump) or mounting bracket (pulley driven pump)and tighten mounting nuts to specified torque.16.Place pump in a bench vise using the mountingflange (gear driven pump) or mounting bracket(pulley driven pump) to hold pump.IMPORTANTDo not clamp vise on pump housing.17.Tighten valve cap to specified torque.Fig. 38 Installing Flow Control Valve1Flow Control Valve2Valve Cap3Valve SpringFig. 39 Discharge Fitting 4-Ring1Discharge Fitting2O-Ring18.Locate discharge fitting in its original position asmarked during disassembly (Figure 40), andtighten jam nut to specified torque.CTS-4027-PAGE 20PRINTED IN UNIED STATES OF AMERICA