S-SERIES INSTRUMENTS1.With the four cluster mounting screws removed,remove a fifth mounting screw from center ofcluster bezel and detach bezel (Figure 6).Figure 6 Removing Instrument Cluster Bezel2.Individual gauges can now be removed byloosening gauge mounting screws as required.All electrically actuated gauges (Figure 7) areremoved from front and have plug-in springloaded connections.Figure 7 Removing Electrically Actuated Water Temperature Gauge3.Speedometer and tachometer (Figure 8) arealso front serviceable and can be removed fromcluster without disconnecting cables. (If cablesare to be removed, these are quick-disconnectfrom rear of cluster, Figure 4.)Figure 8 Removing Tachometer4.Mechanical type air gauges (Figure 9) are frontserviceable after removing air line fittings fromrear of cluster (Figure 5).NOTE - Air gauges are mounted to a commonbracket and are Installed or removed as a pair fromthe cluster body. Also, when reinstalling air linesand fittings, use a non-hardening type sealant onfitting threads.Figure 9 Removing Air GaugesCTS - 4140Y Page 4