SERVICE MANUALDISASSEMBLYSection 2Figure 9. Removing Guide Pin1.Slotted Screw Guide Pin6.Remove six governor cover screws and take offgovernor cover (Figure 10). Lift cover up andoperate control lever to release internal linkage.7.Remove pin retaining clip and link pin anddisconnect floating lever from rack link.8.Pull top of floating lever back and down toremove floating lever and slider (Figure 11) fromguide bushing.NOTE: U sing a rubber band or wire around deliveryvalve secure rack link-up to prevent link damage (Figure11).Figure 10. Removing Governor Cover1.Cover3.Rack Link2.Link Pin4.Floating LeverFigure 11. Removing Floating Lever and Slider1.Floating Lever3.Slider2.Guide Bushing4.Rubber Band orWire9.Raise tabs on lock washer and remove doublenutted thru-bolt and guide bushing from governorflyweight assembly (Figure 12).10.Raise tabs on lock plates, remove two capscrews and take out guide bushing (Figure 13).Figure 12. Removing Thru-Bolt from FlyweightAssembly1.Thru-Bolt3.Guide Bushing2.Flyweight AssemblyCGES-375Printed in United States of AmericaPage 7