S-SERIES AIR CONDITIONING - HEATER SYSTEMTORQUE CHARTAll refrigerant fittings must be lubricated with refrigerant oil prior to tightening. Do not exceed specified torque. Use twowrenches where applicable.TORQUETHREAD SIZEN•mFT.-LB.Condenser Inlet3/4"-1630-35(22-26)Condenser Outlet5/8"-1820-26(15-19)Filter-Dehydrator Inlet11/16"-1615-20(11-15)Filter-Dehydrator Outlet5/8"-1815-20(11-15)Compressor Suction Line1"-1454-60(40-44)Compressor Discharge Line1"-1454-60(40-44)Fan Drive Override Switch7/16"-209-15(7-11)Refrigerant Supply Line to Heater-A/C(Evaporator) Unit5/8"-1820-26(15-19)Refrigerant Return Line from Heater-A/C(Evaporator) Unit1-1/16"-1489-95(66-70)Expansion Valve Inlet5/8"-1820-27(15-20)Expansion Valve Outlet3/4"-1620-27(15-20)Expansion Valve Equalizer Line7/16"-2414-20(10-15)Low Pressure Switch7/16"-209.5-20(7-15)Heater-Evaporator-Blower Unit MountingNuts1/4"-208-11(6-8)Condenser Mounting Bolts5/16"-1815-19(11-14)Filter-Dehydrator Mounting Clamp5/16"-1815-19(11-14)Clutch Retainer Bolt5/16"-2420-27(15-20)Compressor Oil Level Plug------5-15(4-11)Compressor-to-Mounting Bracket Bolts:w/CAT 3208 Engine3/8"-1624-27(18-20)All Other Engines3/8"-1626-31(19-23)Compressor Mounting Bracket-to-EngineBolts3/8"-1641-51(30-38)3/8"-2441-51(30-38)7/16"-1468-81(50-60)1/2"-1395-115(70-85)SPECIAL SERVICE TOOLSThe special service tools and equipment required toservice the S-Series Air Conditioning-Heater System arethe same as those used on IH A/C-Heater Systems ingeneral. Refer to Section CTS-4194 of the ServiceManual for description and illustrations of special servicetools.CTS-4066APage 29