TM 5-3825-226-24
4.
Apply a small amount of silicone grease to
grommet (57) and pull stator wires into stator
housing.
5.
Secure field coil/support assembly (55) with
screws (54).
6.
If removed, install diodes (53) in rectifier bridge
(20).
7.
Secure suppression capacitor (51) with bracket
(52) and screw (50).
8.
Install screws (48) and rectifier bridge (20) with
insulator (49). Tighten screws (48) to a torque of
17.8 to 22.2 lb. in. (2.0 to 2.5 N.m).
9.
Secure connector (21) to rectifier bridge (20) with
screw (46) and washer (47).
10.
Install relay terminal (45), terminal insulators (44,
43, 42), and nut (41).
11.
Attach connector (39) to relay terminal with nut
(40).
12.
Secure other end of connector (39) to regulator
(20) with attaching nut.
13.
Install cap (38) over relay terminal.
14.
Install output terminal (36) with terminal insulator
(37), connector (35), bushing (34), washer (33),
and screw (32).
15.
Install insulator (31) and nut (30) on output
terminal.
16.
Install washer (29), lockwasher (28), and nut (27)
on output terminal.
17.
Secure
regulator
(18)
with
washers
(26),
lockwashers (25), and mounting screws (24).
18.
Connect field coil leads to regulator with screw
(23) and nut (22).
19.
Use nut to secure connector (21) to regulator.
3-10