TM 5-3825-229-14&P
5-15. FUEL INJECTORS
THIS TASK COVERS:
Equipment/Conditions:
a.
Removal
Ref.
Conditions
b.
Installation
4-56
Engine door removed
INITIAL SETUP:
4-49
Air cleaner hose removed
Tools Required:
Equipment/Materials Required:
Nomenclature:
Cleaning solvent (Item 13, Appendix E)
Rags (item 6, Appendix E)
General Mechanics
Goggles (item 6, Appendix E)
Tool Kit
a.
Removal.
WARNING
Wear protective goggles when using the cleaning solvent. Avoid contact with the eyes. If
contact occurs, flush eyes with cold water for 5 minutes and seek immediate medical
attention. Dry cleaning solvent (PD-680) is both toxic and flammable. Avoid prolonged
breathing of vapors. Avoid skin contact. Use only in a well-ventilated area. Keep away
from open flame. Flash point of solvent is 138°F (59C).
(1)
Thoroughly clean injection nozzles (1), lines (2) and surrounding area with cleaning
solvent (PD-680) and a stiff bristle brush.
CAUTION
Failure to clean nozzles, lines and surrounding area will contaminate fuel causing engine
failure.
5-40