TM 5-3895-370-14&Pc. Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;use only in a well-ventilated area; avoid contact with skin, eyes, and clothes and do notbreathe vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 140°F (60°C). Failure to doso may result in injury or death to personnel. P-D-680 type III is a substitute for types I and IIin this application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get fresh air and medicalhelp. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,immediately flush eyes with water and get immediate medical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only witheffective chip guarding and personal protective equipment (goggles/shield, gloves, etc).(1)Clean all parts with drycleaning solvent, rags, and brush. Dry all parts with compressed air.(2)Inspect eye bolts, nuts, and end plugs for worn threads.(3)Inspect springs for cracks, gouges, and chips.(4)Replace damaged parts.d. Assembly.(1)Install two end plugs (9) in spring (1).(2)Install nut (6) on eyebolt (7).(3)Install lockwasher (8), eye bolt (7), and nut (6) onspring (1). Tighten nut.(4)Repeat Step (1) thru (3) for remaining spring.4-449