TM 5-3895-370-14&Pb. Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective gogglesand gloves; use only in a well-ventilated area; avoid contact with skin, eyes, andclothes and do not breathe vapors. Keep away from heat or flame. Neversmoke when using solvent; the flash point for type I drycleaning solvent is100°F (380C) and for type II is 140°F (60°C). Failure to do so may result in injuryor death to personnel. P-D-680 type III is a substitute for types I and II in thisapplication. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(1)Clean gear housing using drycleaning solvent and a lint-free cloth.(2)Check housing for cracks and excessive wear. If damage is found, remove timing pin assembly (para 5-23) andreplace gear housing.c. Installation.(1)Install gear housing gasket (6) on cylinder block(7).(2)Install gear housing (5) with seven screws (4and 3). Tighten screws 18 lb-ft (24 Nm).(3)If removed, Install data plate (2) with two screws(1).(4)If removed, install timing pin (Para 5-23).NOTEFollow-on maintenance:Install camshaft gear (para 5-68).Install fuel injection pump (para 5-31).Install engine oil lube pump (para 5-29).END OF TASK5-61