TM 5-3895-370-14&P
5-28.
ENGINE OIL PAN AND SUMP TUBE REPLACEMENT (CONT).
b.
Cleaning/Inspection.
(1)
Scrape gasket material and sealant from engine block and oil pan.
WARNING
·
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes and do not breathe vapors. Keep away from heat or flame.
Never smoke when using solvent; the flash point for type I drycleaning solvent
is 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result in
injury or death to personnel. P-D-680 type III is a substitute for types I and II in
this application. The flash point for type III is 200°F (93°C).
·
If personnel become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts skin or clothes, flush with cold water.
If solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
(2)
Clean sump tube and oil pan with drycleaning solvent.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only
with
effective
chip
guarding
and
personal
protective
equipment
(goggles/shield, gloves, etc).
(3)
Dry sump tube and oil pan with compressed air.
(4)
Check oil pan for cracks, holes, and other damage.
(5)
Check sump tube for clogged vents, holes, cracks, and other damage.
(6)
Replace damaged parts.
5-66