TM 5-3895-370-14&P5-28.ENGINE OIL PAN AND SUMP TUBE REPLACEMENT (CONT).b.Cleaning/Inspection.(1)Scrape gasket material and sealant from engine block and oil pan.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(2)Clean sump tube and oil pan with drycleaning solvent.WARNINGCompressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Useonly with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc).(3)Dry sump tube and oil pan with compressed air.(4)Check oil pan for cracks, holes, and other damage.(5)Check sump tube for clogged vents, holes, cracks, and other damage.(6)Replace damaged parts.5-66