TM 5-3895-370-14&PWARNINGFuel and oil are slippery and cancause falls. To avoid injury, wipe upspilled fuel or oil with rags.(3)Remove four screws (3) and oil pump (4) fromengine block (5).b.Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc).(1)Clean oil pump in drycleaning solvent and dry with compressed air.(2)Check oil pump gears for chips, cracks, and excessive wear.(3)Check gerotor and inside of oil pump housing for excessive wear and damage.(4)Replace pump if parts are damaged.c.Installation.(1)Lubricate oil pump (4) with engine oil.(2)Install oil pump (4) in engine block (5). Ensure that idler gear shaft engages bore in cylinder block.(3)Install four screws (3). Tighten screws alternately 18 lb-ft (24 Nm).5-69
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business