TM 5-3895-370-14&Pb.Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.·Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment(goggles/shield, gloves, etc.).(1)Clean all metal parts with drycleaning solvent and dry with compressed air or with lint-free cloth.(2)Check all parts for cracks, wear, and rust.(3)Measure length of brushes. Minimum length of used brushes in 0.2 in. (5.08 mm). Minimum length of newbrushes in 0.4 in. (10.16 mm).(4)Replace parts failing inspection.c.Testing.(1)Test rotor for short circuit at points A and B with80 Vac. Indicator lamp must not light up.5-89